in
en

DPS 600 Series GC

After years of development and testing, DPS Instruments, Inc. is pleased to introduce the most expandable and versatile Gas Chromatography Systems in history. The DPS 600 Series GC systems are the world’s only modular GC systems. GC Modules can be mixed to and matched to make 100’s of cost effective, application specific configurations for any GC method! With 9 detectors to choose from, single or double ovens, and built in sample concentrators, we boldly say, “If you can dream it, we can build it!

The DPS 600 Series GC Systems are a new kind of GC. They encompass a state of the art space saving expandable chassis at their core. Our plug -and-play modular components allow for unprecedented performance, and yet all of our GC Systems are easier to build, maintain, and upgrade in the field.
The intelligence of the 600 Series GC Systems are locked safely in microprocessors, where our proprietary Digital Sample Processing routines control the temperatures and gas pressures to tighter specifications than ever before and DSP is what makes our Soft Landing ever so soft.

The DPS 600 Series GC specifications are on par with the biggest selling GC’s in the market, yet they are smaller, lighter, faster, more intelligent, and have delightful pricing.

General Specifications:

- Expandable Modular Design
- 100’s of Standard Application Specific Configurations
- Wind Tunnel Oven and Soft Landing
- Color Touch Screen Instrument Control
- Free standing operation with on-board GC Methods
- Proprietary Digital Signal Processing
- Built-in Instrument Diagnostics
- Temperature Control to 0.001 °C
- EPC Pressure Control to 0.001 kPa
- Ambient to 450 °C Column Oven(s)
- Up to 100 °C per/min Column Oven Ramp
- Fast Cooldown 300 °C to 50 °C in < 4 min
- Compact and Lightweight,
        S series GC (45 x 45 x 45 cm), approximately 25 kg
        D series GC (70 x 45 x 45 cm), approximately 35 kg

 

Electronics Module:

  • Color Touch Screen Instrument Control
  • Enter and store GC Methods via Color Touch Screen
    Actual and set-point display of all GC parameters
    Safety Limits on all user entered parameters
    Oven Temperature Programs (OTP) with Multiple Ramps
    Pressure Programs for Carrier Gases with Multiple Ramps
    Timeline for sequencing Relays, Valves, Traps, etc.
    Detector Control of all Parameters on one page
  • Up to 6 Electronic Pressure Controllers (EPC’s):
  • Atmosphere Pressure & Temperature Compensation
    EPC Pressure Control with 0.1 kPa set point resolution
  • Plug and Play GC Control, Oven, and Detector Boards
  • Microprocessor Control led
    Proprietary Digital Signal Processing
  • Standard Interfaces
  • Liquid and Headspace Autosamplers
    Remote Start and Stop to other lab instruments
    Digital Signal Outputs for each Detector
    Analog Signal Outputs for each Detector
  • Universal voltage input (85 - 240 Vac) with line filter and breaker

 

Detectors:

  • 1-4 Detectors Installed
  • 400°C Temperature Limit with 0.1 °C set-point resolution
  • Multiple Range Analog Output Selection (0-1V, 0-5V & 0-1OV)
  • 24-bit Digital Outputs for each detector via USB
  • EPC Pressure Control with 0.1 kPa set-point resolution
FID — Flame Ionization Detector (100 pg detection limit)
PID — Photoionization Detector (10 pg detection limit)
TCD — Thermal Conductivity Detector (1 ppm detection limit)
HID — Helium Ionization Detector (100 pg detection limit)
NPD — Nitrogen Phosphorus Detector (20 pg detection limit)
TID — Thermoionic Detector (20 pg detection limit)
BCD — Bromine Chlorine Detector (10 pg detection limit)
FPD — Flame Photometric Detector (10 ng Sulfur, 10 pg Phosphorus detection limits)
ECD — Electron Capture Detector (0.1 pg detection limit)

 

Oven Module(s):

  • Column Oven:
  • Ambient to 450 °C Column Oven(s)
    Up to 100°C per/min Oven Ramp
    Fast Cooldown 300 °C to 50°C in 3.5 min
    1000 watt total Heater Elements
    Multiple Temperature Ramps with 0.1 °C set-point resolution
    23 x 23 x 20 cm area for Glass, SS, or Capillary Columns
  • Independent Control of each Column Oven(s)
  • Optional Single Gas Sample Valve and isothermal Valve Oven

 

Injectors:

  • 1 or 2 Installed
  • Split/Splitless and On-column Injectors
    Standard Liners, Fittings, and Septum
    Multiple Pressure Ramps with 0.1 kPa set-point resolution
    400°C Temperature Limit with 0.1 °C set-point resolution

 

Trap Module:

  • Up to 2 electronically actuated Gas Sample Valves
  • 1 or 2 Desorbable Cathedral Traps with Cooling Fan
  • Up to 4 control Solenoids
  • Optional Purge & Trap Concentrator
  • Optional Air Concentrator
  • Optional MicroExtractor
  • Optional Stream Selector
  • Optional Vacuum Pump w/ Flow Control

 

Network Connectivity:

  • Enterprise Compatible Network GC running Windows XPe
  • On Board ETX Computer for GC Control and Data Acquisition
  • Ethernet Connection using Windows Network Protocol
  • Remote Control of GC and Data Acquisition over LAN/WAN/VPN

Data Communications:

  • Bidirectional communication with popular Data Systems
  • Autosampler Control Software
  • Analog and Digital Signal Outputs
  • Start, Stop & GC Ready Output Signals

 


DPS 600 S-Series
Single oven GC
DPS 600 S-Series
Single oven GC +Valve Module
DPS 600 S-Series
Purge & Trap
DPS 600 S-Series
Dual oven GC
DPS 600 S-Series
Dual oven GC + Valve Module

 

For application of DPS GC 600 Series, clik here.

Download brochure, click here.

-- Tampilan terbaik menggunakan Versi terbaru dari Mozilla Firefox, Google Chrome, Internet Explorer, Opera --
Dengan resolusi monitor, minimal 1024 x 768