in
en

DPS COMPANION GC

After years of development and thoughtful consideration, DPS Instruments, Inc. is pleased to introduce the Portable Companion Gas Chromatograph. The Companion GC was designed to “Go with you Anywhere!” Utilizing the same modular plug and play components found in our full size Series 600 Lab GC’s, the performance of the Companion GC has not been compromised because of its small size.

The DPS Companion GC Systems are a new breed of GC. They are the first portable GC where you can select 1 of 7 available detectors, allowing you to do more work in the field than ever before. From Environmental to Forensic, and Homeland Security to Military Applications, the Companion GC goes where you need it. The intelligence of the all DPS GC Systems are locked safely in microprocessors, where our proprietary Digital Sample Processing routines control the temperatures and gas pressures to tighter specifications than ever before and DSP is what makes our Soft Landing ever so soft.

The DPS Companion GC specifications are in a league of their own. The Companion GC and all DPS GC Systems are smaller, lighter, faster, more intelligent, and have delightful pricing.

 

General Specifications:

  • Modular Design
  • Many Standard Application Specific Configurations
  • Compact Oven and Soft Landing
  • Color Touch Screen Instrument Control
  • Free standing operation with on-board GC Methods
  • Proprietary Digital Signal Processing
  • Built-in Instrument Diagnostics
  • Temperature Control to 0.001 C
  • EPC Pressure Control to 0.001 kPa
  • Ambient to 325 C Column Oven(s)
  • Up to 80C per/min Column Oven Ramp
  • Fast Cooldown 325 C to 50 C in < 4 min
  • Compact and Lightweight, Water Tight Carrying Case (52 x 40 x 21 cm) Approximately 10 kg.
  • 1 or 2 compact gas tanks, sold separately.

 

Electronics Module:

  • Enter and store GC Methods via Color Touch Screen
  • Actual and set-point display of all GC parameters Safety Limits on all user entered parameters Oven Temperature Programs (OTP) with Multiple Ramps Pressure Programs for Carrier Gases with Multiple Ramps Timeline for sequencing Relays and Valve Detector Control of all Parameters on one page
  • Up to 2 Electronic Pressure Controllers (EPCs):
  • Atmosphere Pressure & Temperature Compensation EPC Pressure Control with 0.1 kPa set point resolution
  • Plug and Play GC Control, Oven, and Detector Board
  • Microprocessor Controlled Proprietary Digital Signal Processing
  • Digital Signal Outputs for each Detector
  • Universal voltage input (85 - 240 Vac) with line filter and breaker.
  • 7 amps at 48Vdc total power consumption
  • Optional inverter for DC Voltage Input

 

Detectors:

  • 1 Installed
  • 300C Temperature Limit with 0.1 C set-point resolution
  • 24-bit Digital Outputs for the detector via USB
  • EPC Pressure Control with 0.1 kPa set-point resolution

 

Oven Module:

  • Ambient to 325 C Column Oven(s)
  • Up to 80C per/min Oven Ramp Fast Cooldown 325 C to 50C <4 min 200 watt Heater Element Multiple Temperature Ramp with 0.1 C set-point resolution 12.5 x 10.5 x 12.5 cm area for Capillary Columns
  • Optional Single Electronic Gas Sample Valve

 

Injectors:

  • 1 or 2 Installed
  • Split/Splitless modified and non-heated for Gas Samples
  • Cool On-column Injector
  • Multiple Pressure Ramps with 0.1 kPa set-point resolution
  • Up to 2 control Solenoids

 

Data Communications:

  • Bi-directional communication with popular Data Systems
  • Digital Signal Output via USB

 

Network Connectivity:

  • Enterprise Compatible Network GC running Windows XPe
  • On Board ETX Computer for GC Control and Data Acquisition
  • Ethernet Connection using Windows Network Protocol
  • Remote Control of GC and Data Acquisition over LAN/WAN/VPN
Available Detectors:
FID Flame Ionization Detector (100 pg detection limit)
PID Photoionization Detector (10 pg detection limit)
TCD Thermal Conductivity Detector (1 ppm detection limit)
HID Helium Ionization Detector (100 pg detection limit)
NPD Nitrogen Phosphorus Detector (20 pg detection limit)
TID Thermoionic Detector (20 pg detection limit)
ECD Electron Capture Detector (0.1 pg detection limit)

 

For application of portable GC Companion, click here.

Download brochure, click here.

Video of Companion: DPS Companion Portable GC.

 

DPS Companion 2 GC

The portable Gas Chromatograph is now more versatile than ever. DPS Instruments, Inc. is pleased to introduce the Portable Companion 2 Gas Chromatograph with room for 2 Detectors. The Companion 2 GC was designed to “Go with you anywhere!” Utilizing the same modular plug and play components found in our full size Series 600 Lab GC’s, the performance of the Companion 2 GC has not been compromised because of its smaller size.

The DPS Companion 2 GC Systems are a new breed of GC. They are the first portable GC where you can select 2 of 7 available detectors, allowing you to do more work in the field than ever before. From Environmental to Forensic, and Homeland Security to Military Applications, the Companion 2 GC goes where you need it.

The intelligence of the GC Systems is locked safely in microprocessors, where our proprietary Digital Sample Processing routines control the temperatures and gas pressures to tighter specifications than ever before. The DPS Companion 2 GC specifications are in a league of their own. The Companion 2 GC and all DPS GC Systems are smaller, lighter, faster, more intelligent, and have delightful pricing.

General Specifications:

  • Modular Design
  • Many Standard Application Specific Configurations
  • Compact Oven with Soft Landing
  • Color Touch Screen Instrument Control
  • Free standing operation with on-board GC Methods
  • Proprietary Digital Signal Processing
  • Built-in Instrument Diagnostics
  • Temperature Control to 0.001 C
  • EPC Pressure Control to 0.001 kPa
  • Ambient to 325 C Column Oven(s)
  • Up to 80 C per/min Column Oven Ramp
  • Fast Cooldown 325 C to 50 t in <4 min
  • I or 2 Detectors
  • Compact and Lightweight, Water Tight Carrying Case (56 x 43 x 25 cm) with wheels and handle Approximately 15 kg.
  • I or 2 compact gas tanks, sold separately.

 

Electronics Module:

  • Enter and store GC Methods via Color Touch Screen
  • Actual and set-point display of all GC parameters
  • Safety Limits on all user entered parameters
  • Oven Temperature Programs (OTP) with Multiple Ramps
  • Pressure Programs for Carrier Gases with Multiple Ramps
  • Timeline for sequencing Relays, Valve, Pump, etc.
  • Up to 4 Electronic Pressure Controllers (EPCs):
  • Atmospheric Pressure & Temperature Compensation
    EPC Pressure Control with 0.1 kPa set point resolution
  • Plug and Play GC Control, Oven, and Detector Boards
  • Microprocessor Controlled
    Proprietary Digital Signal Processing
  • Universal voltage input (85 - 240 Vac) with line filter and breaker.
  • 7 amps at 48Vdc total power consumption
  • Optional inverter for DC Voltage Input

 

Detectors:

  • 1 or 2 installed
  • 300C Temperature Limit with 0.1 C set-point resolution
  • 24-bit Outputs for the detector via USB
  • EPC Pressure Control with 0.1 kPa set-point resolution

Available Detectors:

FID Flame Ionization Detector (100 pg detection limit)
PID Photoionization Detector (10 pg detection limit)
HID Helium Ionization Detector (100 pg detection limit)
BCD Bromine Chlorine Detector (10 pg detection limit)
FPD Flame Photometric Detector (10 ng Sulfur, 10 pg Phosphorus detection limit)
NPD Nitrogen Phosphorus Detector (20 pg detection limit)
TID Thermoionic Detector (20 pg detection limit)

 

Oven Module:

  • Ambient to 325 C Column Oven(s)
  • Up to 80C per/min Oven Ramp
    Fast Cooldown 325 C to 50C < 4 min
    200 watt Heater Element
    Multiple Temperature Ram with 0.1 C set-point resolution
    12.5 x 18.5 x 14 cm area for Packed, or Capillary Columns
  • Optional Single Electronic Gas Sample Valve
  • Optional Heated Valve Oven
  • Optional Vacuum Pump for Sample Inlet
  • Optional Built-in Ultra Quiet Air Compressor
  • Optional High Pressure Gas Cylinder and Regulator

 

Injectors:

  • 1 or2 Installed
  • Cool On-column Injector
  • Multiple Pressure Ramps with 0.1 kPa set-point resolution
  • Up to 2 control Solenoids

 

Data Communications:

  • Bi-directional communication with popular Data Systems
  • Digital Signal Output via USB

 

Network Connectivity:

  • On Board ETX Computer for GC Control and Data Acquisition
  • Enterprise Compatible Network GC running Windows XP
  • Ethernet Connection using Windows Network Protocol
  • 2 USBs to connect External Devices
  • Remote Control of GC and Data Acquisition over LAN

 

For application of portable GC Companion, click here.

Download brochure, click here.

Video of Companion: DPS Companion Portable GC.
-- Tampilan terbaik menggunakan Versi terbaru dari Mozilla Firefox, Google Chrome, Internet Explorer, Opera --
Dengan resolusi monitor, minimal 1024 x 768