PMD 2450 Precision Microwave Device
Online Microwave Moisture Measurement accuracy of up to 0,1 %
- moisture content of non- and low- conductive materials
optional: area weight compensation
- density of aqueous solutions/ Brix
- concentration of aqueous solutions
optional: compensation of air bubbles
- carbon in flyash
 Advantages:
precise
highly selective on water
inline
contactless measurement of
solids directly at the existing
conveyor without extensive
mechanical sampling devices. Measurement of fluids directly
in pipes.
representative
measuring a large percentage of material due to the transmission geometry. The whole volume is analyzed,not only the surface.
application examples:
coal | minerals | iron ore | magnesite | wood chips | pulp | woodboards | gipsumboards |
steel industry | cement industry | building industry | mining | coal power station | paper industry |
chemical industry | wood industry | food industry

Technical Specifications PMD 2450
cabinet |
protection : IP 65 |
Weight : 9 . 0 kg
dimension: 3O.5 * 24*37.5cm ( H * B * T)
|
display |
touch screen: 114mm >< 64mm
graphical display : 128 X 256 Pixel |
display back light with automatical shut down
touch screen Matrix: 6 x 16
|
power requirement |
90 - 260 \/oll AC, 45 - 65 Hz |
|
measuring principle |
microwave-transmission measurement:
The measured material is transmitted
with microwaves. |
attenuation and phase shifl caused by the material is determined |
microwave |
frequency : 2.4 - 3.0 Ghz
lransmitted power : < 0,01 mW
dynamic range : 50 dB |
precision : < 0,2 dB, < 0,2° / GHz
synchronisation with optional weight compensation |
I/O |
microwave |
2 N-connectors for input and output
2 N-connectors for reference cable |
|
counter :
- area weight compensation
- tachometer |
max. 6 counters, 16 bit
opto-decoupled, pulse width > 0,5 µ s
voltage: 4,5 V - 30 V |
|
digital inpul signals :
- measuremenl (slart/stop)
- sampling (start/stop)
- batch (start/stop)
- belt signal (start/stop) |
8 digital inputs, opto-decoup led |
|
digital outpul signals:
- alarm oulpuls
- general Vault signal |
4 digital oulpuls
open collector
opto-decoupled or relays
|
|
analog input signals:
- area weight compensation
- temperature |
2 x 0/4 - 20 mA or PT 100 analog input 12 bit, in common potential-free |
|
analog output signals |
4 X 0/4 - 20 mA analog aut, 12 bi t, in comm on potential-free |
|
serial interlace |
1 serial interface.
allernalively RS 232 or RS 485 |
sensor |
various antennas or measuring cells |
|
Remote service
is available for all instruments via rrlodem or internel. This saves time and money.
This device is also available with explosion protection for Zone 1 and 2 as well as Zone 21 and 22
|