PMD 2450 Precision Microwave Device

Online Microwave Moisture Measurement accuracy of up to 0,1 %
  • moisture content of non- and low- conductive materials
  • optional: area weight compensation
  • density of aqueous solutions/ Brix
  • concentration of aqueous solutions
  • optional: compensation of air bubbles
  • carbon in flyash

Advantages:

  • precise
  • highly selective on water
  • inline
    contactless measurement of solids directly at the existing conveyor without extensive mechanical sampling devices. Measurement of fluids directly in pipes.
  • representative
  • measuring a large percentage of material due to the transmission geometry. The whole volume is analyzed,not only the surface.

    application examples:
    coal | minerals | iron ore | magnesite | wood chips | pulp | woodboards | gipsumboards | steel industry | cement industry | building industry | mining | coal power station | paper industry | chemical industry | wood industry | food industry

    Technical Specifications PMD 2450

    cabinet

    protection : IP 65

    Weight : 9 . 0 kg

    dimension: 3O.5 * 24*37.5cm ( H * B * T)

     

    display

    touch screen: 114mm >< 64mm

    graphical display : 128 X 256 Pixel

    display back light with automatical shut down

    touch screen Matrix: 6 x 16

     

    power requirement

    90 - 260 \/oll AC, 45 - 65 Hz

     

    measuring principle

    microwave-transmission measurement:

    The measured material is transmitted

    with microwaves.

    attenuation and phase shifl caused by the material is determined

    microwave

    frequency : 2.4 - 3.0 Ghz

    lransmitted power : < 0,01 mW

    dynamic range : 50 dB

    precision : < 0,2 dB, < 0,2° / GHz

    synchronisation with optional weight compensation

    I/O

    microwave

    2 N-connectors for input and output

    2 N-connectors for reference cable

     

    counter :

    - area weight compensation

    - tachometer

    max. 6 counters, 16 bit

    opto-decoupled, pulse width > 0,5 µ s

    voltage: 4,5 V - 30 V

     

    digital inpul signals :

    - measuremenl (slart/stop)

    - sampling (start/stop)

    - batch (start/stop)

    - belt signal (start/stop)

    8 digital inputs, opto-decoup led

     

    digital outpul signals:

    - alarm oulpuls

    - general Vault signal

    4 digital oulpuls

    open collector

    opto-decoupled or relays

     

     

    analog input signals:

    - area weight compensation

    - temperature

    2 x 0/4 - 20 mA or PT 100 analog input 12 bit, in common potential-free

     

    analog output signals

    4 X 0/4 - 20 mA analog aut, 12 bi t, in comm on potential-free

     

    serial interlace

    1 serial interface.

    allernalively RS 232 or RS 485

    sensor

    various antennas or measuring cells

     